• Hst-U300 Ultrasonic Hardness Tester with Multi-Point Calibration
  • Hst-U300 Ultrasonic Hardness Tester with Multi-Point Calibration
  • Hst-U300 Ultrasonic Hardness Tester with Multi-Point Calibration
  • Hst-U300 Ultrasonic Hardness Tester with Multi-Point Calibration
  • Hst-U300 Ultrasonic Hardness Tester with Multi-Point Calibration
  • Hst-U300 Ultrasonic Hardness Tester with Multi-Point Calibration

Hst-U300 Ultrasonic Hardness Tester with Multi-Point Calibration

After-sales Service: Online Technical Support
Type: Ultrasonic Hardness Tester
Measuring Range: Hb, HRC, Hv, Hl
Application: Metal
Standard: ISO, ASTM, GB/T, BSEN
Warranty: 1 Year
Customization:
Manufacturer/Factory, Trading Company
Gold Member Since 2016

Suppliers with verified business licenses

Shandong, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (26)
  • Overview
  • Product Description
  • Company Profile
Overview

Basic Info.

Model NO.
HST-U300
Mobility
Portable
Calibrating Method
Standard Hardness Test Blocks
Rated Voltage
220V
Support Language
English
Customized
Non-Customized
Hardness Tester
Application
Leeb Hardness Tester
Product Name
Transport Package
Carton Box
Trademark
Kason/HST
Origin
Shangdong, China
HS Code
9024800000
Production Capacity
1000

Product Description

HST-U300 Ultrasonic Hardness Tester With Multi-Point Calibration
Hst-U300 Ultrasonic Hardness Tester with Multi-Point Calibration
Product Description

Product overview
There are many types of hardness testing methods,commonly used methods include HB, HRC, HV, HL, etc. But all these methods have boundness. The test force of HB and HRC is strong, so the indentation is big, and the damage to the surface is obvious. HV is tested by optical method, which needs very professional and technical personnel to operate, and cannot directly test large workpiece. And our ultrasonic hardness tester HST-U300 uses ultrasonic contact impedance method to compare and test patterns, this new method brings advantages of high precision, fast speed, portable, easy operation, etc.

Applications
Hardness test of flange edge and gear root stamping parts, mold, thin plate, face-hardened gear tooth, gear groove and taper part
Hardness test of axle and thin-wall pipes and vessels
Hardness test of wheels and turbine rotors
Hardness test of bit edge
Hardness test of welding parts
Measure the depth of deep hole with certain aperture, concave and convex mark with large radians, and irregular plane
Hardness test of most ferrous and nonferrous metals and their alloys in industrial production Etc.

Functional characteristics
New appearance design, innovative sculpt, convenient to hold and good craft.
3.5 inches large LCD screen with 320×480 color graphics dot matrix, beautiful font and graphics, rich information and clear display.
Full English display, menu-type operation, few keys, simple and convenient to operate.
For materials with different elastic modulus, only a simple point calibration is required to adapt to the new material.
Provide multi-point calibration function for any hardness standard. For materials without conversion table, users only need to prepare 2 to 10 test samples with different hardness to directly calibrate the hardness (Hardness standard is arbitrary, as long as these 2 to 10 samples have the same standard).
High accuracy -- ±3 %HV, ± 3%HB, ± 1.5HR (using test stand), according with the test error standard of GB/T-34205, JJF1436 and JB/T9377.
Tiny test indentation - smaller than a Leeb hardness tester and requires a high-power microscope to see.
High test speed -- output test results within 2S.
Easy to test on assembly line -- compare with Leeb hardness tester.
50 sets of data storage -- the data includes time information.
360° test without correction.

Technical Parameters:   

Model HST-U300
Standard DIN50159-1-2008; ASTM-A1038-2005; JB/T 9377-2010; JJG-654-2013; GB\T34205-2017
Range HV50-1599, HRC20-76, HB76-618, HRB41-100, HRB41-100, HRA61-85.6, Mpa255-2180
Test Error HRC: ± 2HRC; HB: ± 3%HB; HV: ± 3%HV
Maximum allowable relative error Hardness of standard test block Maximum allowable relative error of hardness tester %
HV10 HV5 HV2 HV1 HV0.8 HV0.3 HV0.1
<250HV 4 4 4 4 4 5 5
250HV-500HV 4 4 4 4 4 6 6
>500HV-800HV 4 4 5 5 5 7 7
>800HV 4 4 6 6 6 8 8
Probe test force 2kgf(optional 0.5kgf, 1kgf, 5kgf, 10kgf)
Working temperature -20ºC~50ºC
  • Working humidity
<=85%

Probes Parameters:
Probe 0.5kgf manual probe 1kgf manual probe 2kgf manual probe 5kgf manual probe 10kgf manual probe
Accessory Optional accessory Optional accessory Standard accessory Optional accessory Optional accessory
Test force 5N 10N 20N 50N 98N
Diameter 22mm 22mm 22mm 22mm 22mm
Length 150mm 150mm 150mm 150mm 150mm
Resonant rod diameter 2.4mm 2.4mm 2.4mm 2.4mm 2.4mm
Maximum roughness of test surface Ra<3.2um Ra<3.2um Ra<5um Ra<10um Ra<15um
Minimum workpiece weight 0.3kg 0.3kg 0.3kg 0.3kg 0.3kg
Minimum workpiece thickness 2mm 2mm 2mm 2mm 2mm
 
Company Profile

WORK SHOP

Hst-U300 Ultrasonic Hardness Tester with Multi-Point Calibration
 
EXHIBITON
Hst-U300 Ultrasonic Hardness Tester with Multi-Point Calibration
 
OUR Customers all over the world
Hst-U300 Ultrasonic Hardness Tester with Multi-Point Calibration
 
Hst-U300 Ultrasonic Hardness Tester with Multi-Point Calibration
 
CERTIFICATE
Hst-U300 Ultrasonic Hardness Tester with Multi-Point Calibration
 
Packaging&Shipping

Hst-U300 Ultrasonic Hardness Tester with Multi-Point Calibration

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now